Independent Lab Test Results

98.6% of airborne virus, gone in 15 minutes.

Third-party labs put PremierOne germicidal UV units to the test — for virus kill and ozone safety. Here’s exactly what they measured.

MS-2 virus petri dish at start of test, dense with plaques
MS-2 virus — 0 min
Same petri dish after 15 minutes, nearly clear
After 15 min

98.6% of virus inactivated

98.6% airborne virus killed in 15 minutes
<0.003ppm ozone over an 8-hour run (UL 2998)
Pass California CARB 8-hour ozone emissions test
What you’re up against

The three things fouling your indoor air.

31%
Odors & gasses

Volatile organic compounds (VOCs)

35%
Particulate

Organic & inorganic — dust mite dander, smoke, pollen, dust

34%
Bioaerosols

Germs, bacteria, viruses, fungi

LMS Technologies · Forced-Air Recirculating Test

98.6% inactivated in 2½ air exchanges.

Model tested

The PremierOne units were installed in a 16×20 air duct. The test room was 4,000 cubic feet, equivalent to approximately a 500 square foot room. Air was circulated through the test room, and within just 2½ air exchanges, 98.6% of the airborne viruses in the room were inactivated in 15 minutes with our MUV7-100DR dual-lamp unit.

Our units purify the air in the ductwork of the forced-air system, not in the living space of a building.

The wood-framed sealed test room built for the recirculating test
The sealed test room, built to spec.
PremierOne test chamber with blower, duct and measurement equipment
The forced-air recirculating test chamber.
Virus inactivation results
Date Device tested Virus inactivated Air exchanges Chamber size
8/2/2021 MUV-7-100DR-16 98.6% 2.5 4,000 ft³

Equipment 4,000 ft³ Stainless-Steel Test Chamber SKC · BioStage Single-Stage Impactors TSI · Scanning Mobility Particle Sizer (SMPS) 3938

UL 2998 · UL 867 Standard

Our germicidal 254nm units are ozone-free.

Ozone Free badge
<0.003 PPM average over an 8-hour run

The in-duct MUV7-200QR was evaluated to UL 867 (Electrostatic Air Cleaners, Section 40: Ozone test) and the UL 2998 ozone-emission standard. It tested less than 0.003 PPM in an average 8-hour run time — meaning our germicidal-only units are virtually ozone-free.

MUV7-200QR UV lamps mounted in the stainless-steel chamber during ozone testing
The sample under testing — UV lamps in the ozone-emissions chamber.
Ozone concentration line chart staying near zero across the test
Ozone concentration throughout testing (rolling 5-minute average, per UL 2998).
Max ozone test — MUV7-200QR (UL 2998, Table 4)
Measurement UL Ref. Mean Min Max Delta Result
Background C(t) 40.4.3 <0.003<0.0030.0020.002 Pass
Test 1 min C(t) 40.1.2 <0.003<0.003<0.003<0.001 Pass
Test 5 min C(t) 40.1.2 <0.003<0.003<0.003<0.001 Pass

Conditions Chamber supply air flow 583 lpm · Test duration 24 hours (UL 40.4.6) · 2nd sample required: No · Values in PPM

California CARB · Blue Heaven Technologies · July 22, 2021

Passed California’s strict ozone limit with ease.

Model tested
Ozone Safe badge
Passed CARB 8-hour ozone emissions test

The in-duct MUV7-50DR — a unit with adjustable odor control — was evaluated to CSA C22.2 No. 187:20 (Electrostatic Air Cleaners, Section 7.6). It tested 0.005492 PPM in an average 8-hour run time, with a maximum reading over 8 hours of 0.006020 PPM — far below the maximum allowed of 0.0500 PPM. Our units with adjustable odor control passed the test with ease.

For a more detailed explanation, email support@premieroneproducts.com.

Measured (8-hr avg)
0.0055 PPM
CARB limit
0.0500 PPM

Far below the 0.0500 PPM maximum allowed.

CARB 8-hour ozone emissions test — MUV7-50DR
Measurement Reading Maximum allowed Result
Average 8-hour background concentration 0.00193 PPM
Average 8-hour downstream concentration 0.00743 PPM
Average 8-hour time-weighted (TWA) ozone 0.005492 PPM 0.0500 PPM Pass
Maximum ozone reading over 8-hour testing 0.006020 PPM 0.0500 PPM Pass
8-hour ozone concentration chart staying flat near zero, far below the CARB limit line
8-hour ozone concentration at 375 CFM — the measured line (blue) sits far below the 0.0500 PPM limit (red dashed).

Download test results (PDF)

Breathe easier — backed by the lab.

Independently tested to kill airborne virus and stay ozone-safe. Explore the full line of PremierOne germicidal UV units.

PremierOne MUV7-200QR germicidal UV unit